9
Isolation Transformer: used to establish a new neutral-ground bond in order to correct common mode and other grounding problems. A transformer can provide conversion of a Delta system (3 wire) to a Wye connected (4 wire) system. A shielded isolation transformer provides excellent protection from all types of N-G disturbances (impulses, RMS voltage, and high frequency noise). It also protects against voltage transients and spikes while offering full rd galvanic isolation, traps 3 harmonic and triplen harmonics. We hereby introduce ourselves as a manufacturer of dry type power transformers and reactors. We are established in this field since 2003. Our Dry Type Transformer adopt high quality low loss silicon sheet and arranged non-bobbin coil winding technology, and we apply vacuum pressure impregnating (VPI) process and solidify baking process to achieve insulation class H or C. Our transformers are widely used on any occasions where voltage is below 1000V and frequency below 400 Hz, and equipment’s which require voltage to step up or down. For small to medium capacity transformers, we apply enamel wire winding, and we apply foil winding for large capacity ones. Features 1) There are air flows between coil's layer to layer and between coil to core, resulting fast heat dissipation, and low temperature rise. 2) High grade iron core and winding can be wire or foil. 3) Small volume, light weight and good workmanship. 4) After vacuum pressure impregnating, the whole transformers and reactors are moisture proof and mildew proof. Insulation class H or C. 6) Lower audio noise. 7) Nomex based insulation system for foil winding transformers. Type 1) Step up Isolation Transformer 2) Step down Isolation Transformer Testing Our all magnetics are tested as per routine test mentioned as per IS2026. We can carry out other type testing as per your need. Applications of Isolation Transformers There is also some special application of isolating transformers, such us pulse transformers which transmit rectangular pulse signals and provide the electrical isolation. This type is suitable in some computer network designs, CNC machines, etc. Our products range is as under: 1) Single/3 phase Transformer, upto 300KVA, 50Hz - 400Hz. 2) Scott Connected (3phase - 2phase conversion)/ Open delta type (3phase--single phase conversion) 3) Input Chokes for A.C/D.C Drives, from 1hp to 750hp drives 4) Output Chokes for A.C/D.C Drives, from 1hp to 750hp drives 5) DC filter choke 6) Harmonic Filter Choke 7) Transformers for Plasma Welding Machines 8) Transformers with induction heating purpose.
Our Dry Type Transformer adopt high quality low loss silicon sheet and arranged non-bobbin coil winding technology, and we apply vacuum pressure impregnating (VPI) process and solidify baking process to achieve insulation class H or C. Our transformers are widely used on any occasions where voltage is below 1000V and frequency below 400 Hz, and equipments which require voltage to step up or down. For small to medium capacity transformers, we apply enamel wire winding, and we apply foil winding for large capacity ones. Features • There are air flows between coil's layer to layer and between coil to core, resulting fast heat dissipation, and low temperature rise. • High grade iron core and winding can be wire or foil. • Small volume, light weight and good workmanship. • After vacuum pressure impregnating, the whole transformers and reactors are moisture proof and mildew proof. • Insulation class H or C. • Lower audio noise. Type Isolation Transfonner: used to establish a new neutral­ ground bond in order to correct common mode and other grounding problems. A transformer can provide conversion of a Delta system (3 wire) to a Wye connected (4 wire) system. A shielded isolation transformer provides excellent protection from all types of N-G disturbances (impulses, RMS voltage, and high frequency noise). It also protects against voltage transients and spikes while offering full galvanic isolation, traps 3rd harmonic and triplen harmonics.
Auto transformer is kind of electrical transformer where primary and secondary shares same common single winding. So basically it’s a one winding transformer. We hereby introduce ourselves as a manufacturer of dry type power transformers and reactors. We are established in this field since 2003. Our Dry Type Transformer adopt high quality low loss silicon sheet and arranged non-bobbin coil winding technology, and we apply vacuum pressure impregnating (VPI) process and solidify baking process to achieve insulation class H or C. Our transformers are widely used on any occasions where voltage is below 1000V and frequency below 400 Hz, and equipment’s which require voltage to step up or down. For small to medium capacity transformers, we apply enamel wire winding, and we apply foil winding for large capacity ones. Features 1) There are air flows between coil's layer to layer and between coil to core, resulting fast heat dissipation, and low temperature rise. 2) High grade iron core and winding can be wire or foil. 3) Small volume, light weight and good workmanship. 4) After vacuum pressure impregnating, the whole transformers and reactors are moisture proof and mildew proof. Insulation class H or C. 5) Lower audio noise. 6) Nomex based insulation system for foil winding transformers. Type 1). Step up Auto Transformer 2). Step down Auto Transformer Testing Our all magnetics are tested as per routine test mentioned as per IS2026. We can carry out other type testing as per your need. Applications of Auto Transformers Compensating voltage drops by boosting supply voltage in distribution systems. Auto transformers with a number of tapping are used for starting induction and synchronous motors. Auto transformer is used as variac in laboratory or where continuous variable over broad ranges are required. Our products range is as under: 1) Single/3 phase Transformer, upto 300KVA, 50Hz - 400Hz. 2) Scott Connected (3phase - 2phase conversion)/ Open delta type (3phase-single phase conversion) 3) Input Chokes for A.C/D.C Drives, from 1hp to 750hp drives 4) Output Chokes for A.C/D.C Drives, from 1hp to 750hp drives 5) DC filter choke 6) Harmonic Filter Choke 7) Transformers for Plasma Welding Machines 8) Transformers with induction heating purpose.
SERVO CONTROLLED VOLTAGE STABILIZER (SCVS) Both electrical and electronics appliances occupy a prime place of importance in our lifestyle and thus usage of electricity in modern life has substantially increased. But, voltage supply, on the hand, receives very little attention from the consumers. Surprisingly, unstable voltage supply has the potential of causing havoc due to lack of foresight on our part. Even you must have observed the heavy variations in voltage supply during day or night, which results in frequent breakdown, Low production and loss of energy. Thus you need to consider good quality servo controlled voltage stabilizers with various important factors taken into account. This will not only ensure safety but an effective reduction in electricity bills and an increased life span for your sophisticated equipment's. We, Arzoo, are manufacturing servo controlled voltage stabilizers ranging from 1 KVA-1500KVA [conforming to IS:9815] available in multiple configurations, that undergoes through a series of quality tests conducted in our laboratory. In the field of power saving, we expertise for more then Eighteen years, providing total power solutions, prompt and reliable after sales service / support to our customers through an experienced team of service engineers. The ARZOO range of Servo Control (Voltage Stabilizers) are universally recognized as the finest range of servo-controlled voltage stabilizers. The units couple exceptional performance with unequalled build quality to provide an unmatched combination of reliability and versatility. The units are designed to correct power quality problems like brownouts, surges, over-voltage, sags, voltage imbalance, unbalanced current, line noise etc. in the main power supply. Our Servo Control features voltage regulation, isolation, filtering, harmonic cancellation, transient suppression, surge protection, or any combination of these in a one-box solution. Besides that, our patent voltage regulating transformer enabling us to make unique small dimension Servo Control especially for individual regulation. Features : Available from - 1 KVA to 1500 Kva. Correction Rate better than 60 V/sec. Cooling : Natural Air / Oil. Ambient Temperature 0 to 500 C. Selection Auto / Manual. Under / Over Voltage protection. Overload & short - circuit protection. More than 95% efficiency. Timer Control. Built in EMI / RFI Filter.
A voltage regulator is designed to automatically maintain a Constant Voltage level. A voltage regulator may use a simple feed forward design or may include negative feedback. It may use an ElectroMechanical mechanism, or Electronic Components. Depending on the design, it may be used to regulate one or more AC or DC voltages. Electronic voltage regulators are found in devices such as computer Power Supplies where they stabilize the DC voltages used by the processor and other elements. In automobile Alternators and central Power Station Generator plants, voltage regulators control the output of the plant. In an Electric Power Distribution system, voltage regulators may be installed at a Substation or along Distribution Lines so that all customers receive steady voltage independent of how much power is drawn from the line. Automatic Voltage Regulator : Generators, as used in power stations or in standby power systems, will have automatic voltage regulators (AVR) to stabilize their voltages as the load on the generators changes. The first automatic voltage regulators for generators were electromechanical systems, but a modern AVR uses solid-state devices. An AVR is a feedback control system, that measures the output voltage of the generator, compares that output to a set point, and generates an error signal that is used to adjust the excitation of the generator. As the excitation current in the field winding of the generator increases, its terminal voltage will increase. The AVR will control current by using power electronics devices; generally a small part of the generator's output is used to provide current for the field winding. Where a generator is connected in parallel with other sources such as an electrical transmission grid, changing the excitation has more of an effect on the Reactive Power produced by the generator than on its terminal voltage, which is mostly set by the connected power system. Where multiple generators are connected in parallel, the AVR system will have circuits to ensure all generators operate at the same Power Factor. [1] AVRs on grid-connected power station generators may have additional control features to help stabilize the electrical grid against upsets due to sudden load loss or faults.
AUTOMATIC VOLTAGE CONTROLLER (AVC) We command a highly skilled & experienced workforce at our plant guided by a team of competent Engineers having more than 30 years experience in this line. We believe in Quality oriented Products and with State of the art technology. We have established a renowned name as ARZOO ENERGY that has made a major Break-through in the field of engineering and electricity saving. Our high quality product and efficient services to our valued customers have enabled us with ample success. We would like to inform you that we are one of the leading manufacturers of above mentioned products and assure you that we are in a position to supply the same with best quality and strong service after sale. We would like to inform you that in our AVC & Rectifiers, we use Rolling Contact type Regulators where carbon roller are rolling on both sides of the coil, resulting in lesser wear and tear of the system. Also the overall cross-section area of the copper used in these regulators is more, resulting in increase in overall duty cycle of the equipment. The economic life of our stabilizers is easily 15 - 20 years. So, you can plan stabilizers as per your running load, keeping in mind your future expansion plans. VOLTAGE VARIATION: Voltage variation is a common phenomenon all over the country. Generally voltage is low during daytime and high during the night hours. Moreover on holidays, peak hours, rainy days and when the agricultural load is switched off, the voltage rises quite sharply - which is more dangerous. Electrical equipments are designed for 230 Volts (single phase) or 400 Volts (3-phase) and operate with optimum efficiency at its rated voltage. 90% of industrial load consists of motors. Electric Motors draw considerably high current at HIGH voltage and increase energy consumption, increase MDI and reduce power factor etc. These excessive power losses of motors generated at higher voltage results in their premature failure. Similar is the case with Bulbs and Tubes, when voltage increases above 230 Volts. For example, at 270 Volts, the power consumption of 60W-bulb increases almost 40% and the life of bulb reduce from normal 1000 Hours to mere 100 Hours only (as per analysis report of ISI mark bulb manufacturers). The industrial units having high failure rate of electrical equipments i.e. Electric Motors (particularly smaller rating motors up to 7.5 HP), Bulbs, Tubes, Chokes, Contactor coils etc., should verify that it may be due to Higher Voltage. We have supplied number of AVCs to different industries and our clients have confirmed the under noted advantages after installing our AVCs. 1) Up to 60% Reduction in Breakdown of Electrical Equipments 2) 5 - 10% Savings in Electricity Costs (up to 30% on lighting load) 3) Reduction in MDI by 10 - 15% 4) Attractive Pay-back period of 6 - 12 months 5) Improvement in Power Factor 6) Uniform quality of end product & Improved Productivity of the plant 7) Depreciation @ 80% from Indian Income Tax Act. PAY-BACK PERIOD: Owing to its high efficiency (~99.5% in avg. running conditions) and associated benefits, the payback period for ARZOO’S make AVC is typically between 6-12 months, depending upon the number of working hours and duration of high voltage. As required, we are pleased to submit our most competitive offer for Servo Stabilizer in linear regulator technology as hereunder: ‘ARZOO’S make Natural Oil Cooled Type Automatic Voltage Regulator, Copper Wound Suitable for indoor use at a max. amb. Temp. of 45°C, 3-Phase, with the following specs: The standard equipment will primarily consist of the following: a) Linear type continuously variable voltage regulator b) Mode of operation a. Auto Mode (Controller module for sensing and controlling) b. Manual Mode i) With help of Raise/Lower buttons ii) With help of 'T' Handle, if motor fails c) Over Voltage and Under Voltage Protection Inbuilt d) Single Phase protection Inbuilt e) Ammeter with CTs and selector switch f) Voltmeter Selector Switch for I/P & O/P g) Voltage adjust button on controller in Auto mode h) Indications - Input On, Low, High, O/p Cut off i) MCBs for control circuit j) Lifting Lugs k) Drain Valve l) Oil Level Gauge m) Rating Plate n) Earthing Terminal o) Junction Box p) Thermometer Pocket q) Wheels for Uni - directional movement PARAMETER SPECIFICATION TYPE BALANCE / UNBALANCED 3 Phase 4 Wire CAPACITY UPTO 5000 KVA VOLTAGE REGULATOR TECHNOLOGY On load Linear Stepless Rolling Contact mechanism Technology with Carbon Roller Assembly and linearly variable continuous voltage regulator. INPUT VOLTAGE 360 - 450V 350 - 450V 340 - 460V 330 - 470V 320 - 480V 300 - 500V 280 - 460V 260 - 460V 250 - 460V (Ph-Ph) OUTPUT VOLTAGE 380 / 400 / 415 V±1% (Ph – Ph) OUT PUT VOLTAGE ADJUSTMENT 380-415 V in 3 phase Connection Star Operating Frequency 47 – 53 HZ Waveform No distortion Output regulation 1% maximum from No load to full load Motor Drive Heavy Duty Synchronous Motor COOLING ONAN Operating temp Normal 0-45 C Temp Rise 45 C above ambient DUTY CYCLE 100% continuous LOAD CYCLE 100 % Continuous CORE USED CRGO M4 Grade 0.27mm thickness COPPER USED 99.9 % pure Electrolytic Grade Buck-Boost Transformer Yes, Series Buck Boost Double Wound Transformer TESTING Routine tests - No load, Full load, Short Circuit, Heat run, capacity, Range ELECTRONIC CONTROL CIRCUIT IC – Based RESPONSE TIME 10 milli seconds CORRECTION TIME 8-10 Volts/sec OVER LOAD CAPACITY Our Linear Regulator type Automatic Voltage Stabilizer will be very much suitable to withstand 120% over load Efficiency more than 98% Standard As per IS 9815 TERMINATIONS Separate Suitable Aluminum Bus Bars will be provided in the Termination Box. EXPECTED WORKING LIFE More than 25 Years. MODE OF OPERATION AUTO MODE MANUAL MODE (i) With raise / lower switch (ii) With “T” handle Controls Control will be provided in the same system on the front of the equipment TRANSFORMER OIL AS PER IS: 335
Servo Controlled Voltage Stabilizer : The Servo Stabilizers uses an advanced electronic servo-motor concept to control a motorized variable transformer. Because of the motorization, there is a small delay in voltage correction. However, output voltage accuracy is usually ± 1% with input voltage changes up to ± 50%. These machines are not affected unduly by power factor or frequency variation. This type of technology tends to be extremely effective when considering large three phase applications, as it is able to maintain its accuracy of all three phases, both line to line and line to neutral, irrespective of input voltage balance and load balance at any power factor. They are also able to withstand large inrush currents, normally experienced with inductive loads. However due to the mechanics of this type of stabilizer, periodic maintenance is required. ADVANTAGES OF USING SERVO STABILIZERS: CONTROLLED & CONSTANT VOLTAGE REDUCED FAILURE RATE OF ELECTRICAL EQUIPMENTS REDUCTION IN THE DOWNTIME / MAINTENANCE EXPENSES IMPROVEMENT IN THE POWER FACTOR REDUCTION IN THE MDI (MAXIMUM DEMAND) MDI = Rating of the equipment/ (Power Factor X Efficiency ) IMMEDIATE RESPONSE TO INPUT TRANSIENT SURGES ENERGY SAVER-REDUCTION IN POWER WASTAGE (LOWER ELECTRICITY BILLS) 100% DEPRECIATION CAN BE CLAIMED UNDER INCOME TAX RULES BEING ENERGY SAVER EQUIPMENT PREVENTS FIRE, ACCIDENTS, PRODUCTION AND HUMAN LIFE LOSS. APPLICATIONS: OFFSET PRINTING MACHINES CNC MACHINES SIGNALLING RADARS TELECOMMUNICATION EXCHANGES AIR CONDITIONING PLANTS ESCALATORS & ELEVATORS MEDICAL EQUIPMENTS GENERAL LABORATORY EQUIPMENTS HOSPITALS INDUSTRIAL & LIGHTING LOADS AC MOTORS HOTELS PETROL PUMPS LATHE MACHINES and many more.....
P3 System : Voltage variation is a common phenomenon all over the country. Generally voltage is low during daytime and high during the night hours. Moreover on holidays, peak hours, rainy days and when the agricultural load is switched off, the voltage rises quite sharply, which is more dangerous. Electrical equipment's are designed for 230 Volts (single phase) or 400 Volts (3-phase) and operate with optimum efficiency at its rated voltage. 90% of industrial load consists of motors. Electric Motors draw considerably high current at HIGH voltage and increase energy consumption, increase MDI and reduce power factor etc. These excessive power losses of motors generated at higher voltage results in their premature failure. Similar is the case with Bulbs and Tubes, when voltage increases above 230 Volts. For example, at 270 Volts, the power consumption of 60W-bulb increases almost 40% and the life of bulb reduce from normal 1000 Hours to mere 100 Hours only (as per analysis report of ISI mark bulb manufacturers). The industrial units having high failure rate of electrical equipments i.e. Electric Motors (particularly smaller rating motors up to 7.5 HP), Bulbs, Tubes, Chokes, Contactor coils etc., should verify that it may be due to Higher Voltage. We have supplied number of P3 Systems to different industries and our clients have confirmed the under noted advantages after installing our AVCs. Features : • Up to 60% Reduction in Breakdown of Electrical Equipments • 5 - 10% Savings in Electricity Costs (up to 30% on lighting load) • Reduction in MDI by 10 - 15% • Attractive Pay-back period of 6 - 12 months • Improvement in Power Factor • Uniform quality of end product & Improved Productivity of the plant • Depreciation @ 80% from Indian Income Tax Act. PAY-BACK PERIOD: Owing to its high efficiency (~99.5% in avg. running conditions) and associated benefits, the payback period for ARZOO’S make P3 System is typically between 6-12 months, depending upon the number of working hours and duration of high voltage.
While working of many Electrical Devices many Harmonics are created which can cause a great Damage to the system. To avoid this Harmonics in the circuit and damage to the circuit the technology of using filters was introduced. We Arzoo Energy having Experience of more than 13 years as the famous Manufacturer of many Electrical Products.We are also wellknown manufacturer of Filters. Product Name: Active Filters Technical Advantages: 1.Improves instantaneous as well as average power factor to necessary level. 2.Reduces total Harmonic distortion for current as well as voltage within International IEEE 519 standards. 3.Excellent dynamics with a response time of less than 0.2 milliseconds. 4.Does not allow harmonics to enter the system from the surrounding facilities, making the system more robust. 5. Reduces system losses drastically. 6. Provides equally good compensation, even in case of voltage sags. 7. Does not affect the normal operation of the system even in case of failures. Economic Advantages: 1.Reduces the overall Energy bills. 2. Increases capacity utilization of the source. 3.Ensures proper functioning of the overall system. 4.99.99% uptime guarantee. 5. Decrease the maximum demand of the system as well as the generator. 6.No overloading of UPS or generator sets. 7. Increases efficiency of the generator sets and ensures maximum utilization. 8. Increases life of sensitive lab equipment's and ensures proper functioning through quality power supply. 9.Smaller footprint reduces cost for space. 10.Increases life of Industrial cables. 11.Virtually maintenance free