http://thane.arzooenergy.in
ARZOOTHANE ARZOOTHANE 58ca9f092b1f7e053860c747 False 1027 12
OK
background image not found
Found Update results for
'induction heating purpose'
9
Isolation Transformer: used to establish a new neutral-ground bond in order to correct common mode and other grounding problems. A transformer can provide conversion of a Delta system (3 wire) to a Wye connected (4 wire) system. A shielded isolation transformer provides excellent protection from all types of N-G disturbances (impulses, RMS voltage, and high frequency noise). It also protects against voltage transients and spikes while offering full rd galvanic isolation, traps 3 harmonic and triplen harmonics. We hereby introduce ourselves as a manufacturer of dry type power transformers and reactors. We are established in this field since 2003. Our Dry Type Transformer adopt high quality low loss silicon sheet and arranged non-bobbin coil winding technology, and we apply vacuum pressure impregnating (VPI) process and solidify baking process to achieve insulation class H or C. Our transformers are widely used on any occasions where voltage is below 1000V and frequency below 400 Hz, and equipment’s which require voltage to step up or down. For small to medium capacity transformers, we apply enamel wire winding, and we apply foil winding for large capacity ones. Features 1) There are air flows between coil's layer to layer and between coil to core, resulting fast heat dissipation, and low temperature rise. 2) High grade iron core and winding can be wire or foil. 3) Small volume, light weight and good workmanship. 4) After vacuum pressure impregnating, the whole transformers and reactors are moisture proof and mildew proof. Insulation class H or C. 6) Lower audio noise. 7) Nomex based insulation system for foil winding transformers. Type 1) Step up Isolation Transformer 2) Step down Isolation Transformer Testing Our all magnetics are tested as per routine test mentioned as per IS2026. We can carry out other type testing as per your need. Applications of Isolation Transformers There is also some special application of isolating transformers, such us pulse transformers which transmit rectangular pulse signals and provide the electrical isolation. This type is suitable in some computer network designs, CNC machines, etc. Our products range is as under: 1) Single/3 phase Transformer, upto 300KVA, 50Hz - 400Hz. 2) Scott Connected (3phase - 2phase conversion)/ Open delta type (3phase--single phase conversion) 3) Input Chokes for A.C/D.C Drives, from 1hp to 750hp drives 4) Output Chokes for A.C/D.C Drives, from 1hp to 750hp drives 5) DC filter choke 6) Harmonic Filter Choke 7) Transformers for Plasma Welding Machines 8) Transformers with induction heating purpose.
Auto transformer is kind of electrical transformer where primary and secondary shares same common single winding. So basically it’s a one winding transformer. We hereby introduce ourselves as a manufacturer of dry type power transformers and reactors. We are established in this field since 2003. Our Dry Type Transformer adopt high quality low loss silicon sheet and arranged non-bobbin coil winding technology, and we apply vacuum pressure impregnating (VPI) process and solidify baking process to achieve insulation class H or C. Our transformers are widely used on any occasions where voltage is below 1000V and frequency below 400 Hz, and equipment’s which require voltage to step up or down. For small to medium capacity transformers, we apply enamel wire winding, and we apply foil winding for large capacity ones. Features 1) There are air flows between coil's layer to layer and between coil to core, resulting fast heat dissipation, and low temperature rise. 2) High grade iron core and winding can be wire or foil. 3) Small volume, light weight and good workmanship. 4) After vacuum pressure impregnating, the whole transformers and reactors are moisture proof and mildew proof. Insulation class H or C. 5) Lower audio noise. 6) Nomex based insulation system for foil winding transformers. Type 1). Step up Auto Transformer 2). Step down Auto Transformer Testing Our all magnetics are tested as per routine test mentioned as per IS2026. We can carry out other type testing as per your need. Applications of Auto Transformers Compensating voltage drops by boosting supply voltage in distribution systems. Auto transformers with a number of tapping are used for starting induction and synchronous motors. Auto transformer is used as variac in laboratory or where continuous variable over broad ranges are required. Our products range is as under: 1) Single/3 phase Transformer, upto 300KVA, 50Hz - 400Hz. 2) Scott Connected (3phase - 2phase conversion)/ Open delta type (3phase-single phase conversion) 3) Input Chokes for A.C/D.C Drives, from 1hp to 750hp drives 4) Output Chokes for A.C/D.C Drives, from 1hp to 750hp drives 5) DC filter choke 6) Harmonic Filter Choke 7) Transformers for Plasma Welding Machines 8) Transformers with induction heating purpose.
We Arzoo Energy ISO 9001 : 2000, CE, CRISIL certified company that provides state of the art energy power saving products for Industries and Businesses alike. Arzoo Energy aspires to offer the widest range of Power Saving Products for all purposes, be it for Industrial, Commercial or Residential usage.It has been our continuous endeavor to provide Innovative Electrical Products that could perform effectively and efficiently save Power in all possible applications. We work on Slogan " Save Power , Save Nation"
We Arzoo Energy the leading Manufacturer and Exporter of Industrial Automatic Voltage Controller (AVC) upto 500KVA , Silicon Power Rectifiers (0-500V, up to 2000 Amps), Distribution & Power Transformer up to 15 MVA with 11/22/33 KV Class, HT & Built in AVRs, Dry type & Isolation Transformers along with Special Purpose Transformers. We Command a highly skilled & experienced workforce at our plant guided by a team of competent Engineers which are highly experienced in this line. We believe in Quality oriented products and with State of the Art technology. We have established a renowned name as Arzoo Energy that has made a major Break-through in the field of engineering and electricity saving. Our high quality product and efficient services to our valued customers have enabled us with ample success. We would like to inform you that we are one of the leading manufacturers of above mentioned products and assure you that we are in position to supply the same with best quality and strong services after sale. We would like to inform you that in our AVC and rectifiers, we use Rolling contact type regulators where carbon roller are rolling on both sides of the coil, resulting in lesser wear and tear of the system. Also the overall cross-section area of the copper used in these regulators is more, resulting in increase in overall duty cycle of the equipment. The economic life of our stabilizers is easily 15-20 years. So, you can plan stabilizers as per your running load , keeping in mind your future expansions plans.
Here is a smart way to reduce 10% to 20% of your electricity consumption monthly. This new innovative device Auto True Micro Power Saver (ATMPS) can filter & Stabilize the supply voltage while improving the efficiency and power factor of your electricity consumed. This Auto True Micro Power Saver (ATMPS) Device is able to store electricity for 5 to 10 seconds and release it for use doing downside voltage. It can also improve safety by reducing the overheating of electrical wiring, hence reducing the size of wiring an copper loss, low & high voltage protection, earth leakage & delay on circuit which protect your electronic & electrical appliances and improve their life. (Precaution should be observed here, this does not imply that attaching multiple units of the power saver will drastically reduce power consumption in all cases. Please consult a trained electrician if advice is necessary.) Most Commercial / Industries have consistently shown that one unit of the Power Saver will save 3 to 4 kWh per day, based on electrical consumption of 30 kWh per day. The amount depends on few factors such as the type of electrical appliance use, the amount of electrical use and location. Places near to shops, restaurants and light industries where voltage supply is unstable and fluctuating will see higher savings. In addition to extending the life span of appliance motor, this device also reduces the reactive power generated by inductive loads. It helps the utility companies by eliminating interference to the power supply. The ATMPS is a microprocessor based system, displays the Electrical parameters like Voltage. Features: • Save Electricity upto 20% . • Improve Power Factor . • Reduce Transmission Loss . • Eliminates overheating of wiring and appliances . • Protect against surges and spikes . • Stabilizes voltage . • Input Voltage Range : 200V to 270V (P-N). • Output Voltage : 230V (P-N). • Type of Machine : 1 / 3 Phase Unbalanced Units. • Efficiency : More than 98% at full load. • Output Wave-form : No distortion input waveform i.e sine wave 60 V/ Second. • Maintenance Free. • Increases the life of your electronic appliances . Technical Aspect: There are two components of power: Reactive Power And Working (Real) Power. Reactive power (KVAR) is used to create Electromotive Force(EMF) in the inductive loads in your home and business. This power performs no "real" work. Working power (KW) is the power that performs the function of the load. These two components combine to formulate Apparent Power (KVA), the total power which the load consumes. Apparent power is equal to the square root (sqrt) of (KW)^2 +( KVAR)^2. Power Factor is the ratio of working power (KW) to apparent power (KVA). In other words looking at all the power that a load consumes, how much of it (percentage wise) is used to perform the real work.
AUTO TRUE MICRO POWER SAVER (ATMPS) : Electrically controlled equipment is a major contributor to harmonics found in your electrical system. It can be a “silent killer” in your facility, leading to operational problems with both electrical and electronic equipment including mis-operation, shutdown and early failure. Harmonics may affect specific points of virtually all apsects of your electrical system, including lowering your power factor, which raises your utility costs. ARZOO harmonic filter will perform mitigation for a wide array of needs. This includes equipment to help reduce amplification of harmonics when capacitors are automatically switched, to suppress one or more specific harmonic orders, and to lessen a broad range of multiple harmonic orders. Education, awareness and assistance from ARZOO can help to maximize your operation’s uptime and bottom line. Features : Saver Power up to 20%. Increases the Life of Electric Device. Reduce Transmission Loss. Protect against Surges and Spikes. Stabilizes Voltage. Maintenance Free. Environment Friendly. Improve Power Factor. Eliminates Overheating of Wiring and Appliances. Uniform Electric Current. Saves Energy Efficiently. Two Years Guarantee.
Harmonic Distortion Sources and Effects Events over the last several years have focused attention on certain types of load on the electrical system that results in power quality problems for the user and utility Equipment which has become common place in most of the facility. Non - linear loads generates voltage and current harmonics, which can have adverse effect on equipments, which are designed for operation as linear loads (i.e. Loads designed to operate on a sinusoidal waveform of 50 or 60 Hz.) Effects of non-linear load: Higher heating losses in the transformers Harmonic can have a detrimental effect on emergency generators, telephone and other sensitive electrical equipments. When receive power compensation (in the form of passive power factor improving capacitors) is used with non-linear loads, resonance condition can occur that may result in even higher levels of harmonic voltage and current distortion, thereby causing equipment failure, disruption of power services, and fire hazards in extreme conditions. The electrical environment has absorbed most of these problems in the past. However, the problem has now increased in a magnitude where Europe, the US, and other countries have proposed standards to responsible engineer system considering the electrical environment. IEEE 519-1992 and IEC 555 have evolved to become a common requirement cited when specifying equipment on newly engineered projects. The broad band harmonic filter was designed in part, to meet this specification. The present IEEE 519-1992 document establishes acceptable levels of harmonics (voltage and current) that can be introduced into the incoming feeders by commercial and industrial users. Where there may have been little cooperation previously from manufacturing to meet such specification, the adoption of IEEE 519-1992 and other similar world standards now attract the attention of everyone. Generation of harmonics: Harmonics are sinusoidal wave forms. They have frequency in multiple of fundamental frequency. They are produced by equipment using frequency conversion technology. They are also generated due to power drawing pattern of non-linear loads. Mitigation of Harmonic Distortion For resolution of harmonic problem, various techniques have been proposed to reduce the impact of load harmonic currents on the input current to an electrical system. Essentially, the intent of all these techniques is to make the input current more continuous so as to reduce the overall current harmonic distortion. The various techniques can be classified into four broad categories, a) The use of line reactors and / or DC link chokes b) Installation of passive filters (series, shunt, and low pass broad brand filters) c) Phase multiplication (12-pulse, 18-pulse rectifier system.) d) Harmonic compensation by active filtering. Harmonic protection filters are used for improvement of power factor and part elimination of harmonics. They are nothing but a combination of reactors and capacitors, suitably detuned. They are useful when distortion is 15 to 40 %. Advantages of Harmonic Filters: a) Protect capacitors from harmonic overloading. b) Eliminate upto 97 % predominant harmonics. c) Avoid harmonic amplification in the system. d) Improve power factor. This system can be configured to operate in fully automatic mode. The objective is to eliminate high level of harmonic current to acceptable level to comply with utility regulation. They provide traps for individual harmonics frequency and provide reactive power compensation at fundamental frequency. Harmonic filtering offers the following benefits: 1) Elimination of power factor penalty. 2) Improvement in reduction in energy bill.( due to improvement of PF) 3) Release of additional VA capacity in the system. 4) Improvement in voltage profile. 5) Reduction in line losses 6) Reduction in harmonic currents. 7) Improvement in overall power quality. 8) Improvement in life of electrical equipment. 9) Improvement in system reliability.
Harmonic Distortion Sources and Effects Events over the last several years have focused attention on certain types of load on the electrical system that results in power quality problems for the user and utility Equipment which has become common place in most of the facility. Non - linear loads generates voltage and current harmonics, which can have adverse effect on equipments, which are designed for operation as linear loads (i.e. Loads designed to operate on a sinusoidal waveform of 50 or 60 Hz.) Effects of non-linear load: Higher heating losses in the transformers Harmonic can have a detrimental effect on emergency generators, telephone and other sensitive electrical equipments. When receive power compensation (in the form of passive power factor improving capacitors) is used with non-linear loads, resonance condition can occur that may result in even higher levels of harmonic voltage and current distortion, thereby causing equipment failure, disruption of power services, and fire hazards in extreme conditions. The electrical environment has absorbed most of these problems in the past. However, the problem has now increased in a magnitude where Europe, the US, and other countries have proposed standards to responsible engineer system considering the electrical environment. IEEE 519-1992 and IEC 555 have evolved to become a common requirement cited when specifying equipment on newly engineered projects. The broad band harmonic filter was designed in part, to meet this specification. The present IEEE 519-1992 document establishes acceptable levels of harmonics (voltage and current) that can be introduced into the incoming feeders by commercial and industrial users. Where there may have been little cooperation previously from manufacturing to meet such specification, the adoption of IEEE 519-1992 and other similar world standards now attract the attention of everyone. Generation of harmonics: Harmonics are sinusoidal wave forms. They have frequency in multiple of fundamental frequency. They are produced by equipment using frequency conversion technology. They are also generated due to power drawing pattern of non-linear loads. Mitigation of Harmonic Distortion For resolution of harmonic problem, various techniques have been proposed to reduce the impact of load harmonic currents on the input current to an electrical system. Essentially, the intent of all these techniques is to make the input current more continuous so as to reduce the overall current harmonic distortion. The various techniques can be classified into four broad categories, a) The use of line reactors and / or DC link chokes b) Installation of passive filters (series, shunt, and low pass broad brand filters) c) Phase multiplication (12-pulse, 18-pulse rectifier system.) d) Harmonic compensation by active filtering. Harmonic protection filters are used for improvement of power factor and part elimination of harmonics. They are nothing but a combination of reactors and capacitors, suitably detuned. They are useful when distortion is 15 to 40 %. Advantages of Harmonic Filters: a) Protect capacitors from harmonic overloading. b) Eliminate upto 97 % predominant harmonics. c) Avoid harmonic amplification in the system. d) Improve power factor. This system can be configured to operate in fully automatic mode. The objective is to eliminate high level of harmonic current to acceptable level to comply with utility regulation. They provide traps for individual harmonics frequency and provide reactive power compensation at fundamental frequency. Harmonic filtering offers the following benefits: 1) Elimination of power factor penalty. 2) Improvement in reduction in energy bill.( due to improvement of PF) 3) Release of additional VA capacity in the system. 4) Improvement in voltage profile. 5) Reduction in line losses 6) Reduction in harmonic currents. 7) Improvement in overall power quality. 8) Improvement in life of electrical equipment. 9) Improvement in system reliability.
VOLTAGE STABILIZER : All electrical and electronic systems are designed and manufactured to operate at maximum efficiency with a given supply voltage, called the nominal operating voltage. For various reasons the voltage of the energy distribution does not remain constant, showing considerable fluctuations in the nominal value, which leads to the apparatus, not only a loss of efficiency (sometimes even the impossibility of operation), but also a significant increase in failure rate. The Stabilizers are electronic devices responsible for correcting the voltage of the electrical power supply to provide a stable and secure power supply to equipments, allowing for a stable voltage and protecting the equipment from most of the problems of the mains. Like UPS, Voltage Stabilizers are an asset to the protection of electrical and electronic equipment. The main function of a Stabilizer is to make the output voltage that feeds the equipments connected to it as much as possible equivalent to the ideal electrical power supply, ensuring that the oscillations in electrical power are offset, and its output maintain a stable value, preventing them from being experienced by equipments and thereby avoiding their damage. Most Stabilizers also have electronic filters whose purpose is to suppress noise and peak voltage.
1
91
false